Bay BayStack 400-ST1 Instrukcja Obsługi Strona 1

Przeglądaj online lub pobierz Instrukcja Obsługi dla Networking Bay BayStack 400-ST1. Bay BayStack 400-ST1 Instruction manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Cascade Module

Part No. 304433-B Rev 00August 2000 TMInstalling the BayStack 400-ST1 Cascade Module

Strona 2

8Base UnitThe base unit is a unique unit that can be selected by the Unit Select switch on the front panel of the 400-ST1 cascade module (see “Unit S

Strona 3 - Introduction

9•Initial installation -- During the initial installation of the stack, the software automatically determines the physical order of all units in the

Strona 4

10-- If there is only one Business Policy Switch unit in your mixed stack configuration, and it fails, the next upstream BayStack 450 Switch unit wil

Strona 5

11•Stack MAC address -- The stack MAC address is automatically assigned during the stack initialization. The base unit’s MAC address, with an offset,

Strona 6 - Contents of Shipment

12Stack ConfigurationsAs shown in Figure 5, the cascade connectors and cables on the 400-ST1 front panel provide the ability to stack up to eight swi

Strona 7

13Figure 5. Stack Up Configuration ExampleUnit 7Unit 81 = Last unit2 = Base unit3 = Cascade cable (PN 303978-A)4 = Cascade max-return cable (PN 30397

Strona 8

14Stack Down ConfigurationsIn Figure 6, data flows from the base unit (unit 1) to the next switch, which is assigned as unit 2, and continues until t

Strona 9 - Cascade A InUnit Select

15Figure 6. Stack Down Configuration ExampleUnit 21 = Base unit2 = Last unit3 = Cascade cable (PN 303978-A)4 = Cascade max-return cable (PN 303979-A)

Strona 10

16Redundant Cascade Stacking FeatureBayStack 400-ST1 Cascade Modules allow you to connect up to 8 units into a redundant cascade stack. If any single

Strona 11 - Temporary Base Unit

17Figure 7. Redundant Cascade Stacking FeatureUnit 21 = Base unit2 = Last unit3 = Cascade cable (PN 303978-A)4 = Cascade max-return cable (PN 303979-

Strona 12 - Automatic failover

© 2000 by Nortel Networks, Inc.All rights reserved. Printed in the USA. August 2000.TrademarksNortel Networks and BayStack are trademarks of Nortel N

Strona 13 - Stack MAC address

18InstallationThis section describes how to connect up to eight switches into a redundant stack. The stack can consist of any combination of supporte

Strona 14 - Stack Up Configurations

19Installing the 400-ST1 Cascade ModuleThe Cascade Module slot on supported switches can accommodate a single 400-ST1 Cascade Module.To install a 400

Strona 15

20•Business Policy Switch -- Use a flat-blade screwdriver to gently pry off the filler panel (Figure 9).Figure 9. Business Policy Switch Filler Panel

Strona 16

21Figure 10. Installing a 400-ST1 Cascade Module4. Press the module firmly into the chassis slot. Make sure that the module is fully seated into the

Strona 17

22Installing and Connecting Multiple SwitchesThe procedure to install and connect multiple switches is similar for standard 19-inch utility rack, she

Strona 18

235. Set the Unit Select switch for the base unit to the Base (up = Base) position (Figure 11).6. Set the Unit Select switch for all other units in t

Strona 19

247. Connect the units using the supplied cascade cables (Figure 12).a. Connect one end of a cascade cable to the Cascade A Out connector on the Base

Strona 20 - Installation

25b. Connect the other end of the cascade cable to the Cascade A In connector on the unit just below the base unit (unit 2), or just above the base u

Strona 21 - BayStack 450 and 410-24T

26Connecting PowerWhen the stack is initially powered up, the software automatically assigns unit numbers to the units (the individual switches in th

Strona 22 - Business Policy Switch

272. Plug the other ends of the AC power cords into a grounded AC power strip.One or two AC power strips may be required to accommodate the quantity

Strona 23 - Unit Select

1IntroductionThis guide shows how to install BayStack™ 400-ST1 Cascade Modules into the following supported switches1:• Nortel Networks Business Poli

Strona 24

28Figure 13. Verifying the Installation• The Base LED for the base unit only is on.If one (or more) Base LEDs are blinking, no unit (or more than one

Strona 25

29Modifying an Existing Stack ConfigurationThis section provides examples of how to modify an existing stack configuration. The examples assume the s

Strona 26 - (unit 1)

30Assigning a New Base Unit to the StackTo assign a new base unit to the stack, complete the following steps:1. Set the Unit Select switch on the ori

Strona 27

31Adding Units to the StackThis section describes how to add one or more units to the middle of a stack or to the end of a stack.Adding Units to the

Strona 28

32For tabletop configurations, temporarily move units 1 and 2 to allow space for units 5 and 6.Figure 14. Adding to Middle of Stack4. Add the new uni

Strona 29

335. Reconnect the cascade cable from unit 2 to the Cascade A In connector of (new) unit 5.6. Connect a cascade cable from the Cascade A Out connecto

Strona 30 - 2 = All other units in stack

34Figure 15. Adding to End of Stack2. Disconnect the cascade return cable (item 4) from the Cascade A Out connector at unit 4.Leave the other end of

Strona 31 - Configuration

354. Connect a cascade cable from the Cascade A Out connector of unit 4 to the Cascade A In connector of unit 5.5. Connect a cascade cable from the C

Strona 32

36Removing/Replacing Adjacent UnitsTo remove/replace adjacent units from an operating stack, complete the following steps (Figure 16):1. Remove the c

Strona 33

372. Remove the cascade cable from the Cascade A In connector at unit 5.3. Remove the units (units 3 and 4) and install replacement units as required

Strona 34

2As shown in Figure 1 on page 1, in a mixed stack configuration, the BayStack 450 and 410-24T switches must use compatible but device-specific softwa

Strona 35

385. Repeat steps 1 to 4 for unit 5.Figure 17. Removing Nonadjacent Units6. Renumber the order of the units for the new stack configuration (if desir

Strona 36

39Upgrading the Switch FirmwareYour switch firmware provides a code load facility that allows you to upgrade the firmware image over any switch port,

Strona 37

40Accessing the Latest DocumentationIf you are upgrading your switch, be sure to obtain the latest version of the switch’s User Guide. You can obtain

Strona 38

3You can obtain the latest updates to your product documentation, including release notes, by visiting the Nortel Networks Web site at the following

Strona 39

4Contents of ShipmentYour BayStack 400-ST1 shipment includes the following items (Figure 2):Figure 2. Contents of ShipmentItem DescriptionPart Number

Strona 40

5If any items are missing or damaged, contact the sales agent or the customer service representative from whom you purchased the BayStack 400-ST1 cas

Strona 41 - Upgrading the Switch Firmware

6Cascade A Out ConnectorProvides an attachment point for connecting this unit to another unit via the cascade cable. A cascade return cable from anot

Strona 42

7Figure 4. Connecting Cascade CablesCascade A OutUnit 1Cascade A OutCascade A InUnit 21 = Base unit2 = 303978-A cascade cable3 = 303978-A cascade cab

Komentarze do niniejszej Instrukcji

Brak uwag